beautypg.com

Hardware preparation and installation – Artesyn ARTM-9405 16x10GbE Installation and Use Guide (May 2014) User Manual

Page 24

background image

Hardware Preparation and Installation

ARTM-9405 16x10GbE Installation and Use (6806800P45F)

24

A permanently lit LED indicates that the payload of both the front blade and RTM has been
powered down.

4. Unlatch the upper handle, and then rotate both handles fully outward.

5. Remove the interface cables from the face plate connectors, if applicable.

6. Loosen the screws on the RTM face plate.

7. Remove the RTM from the slot.

Data Loss
Removing the product with the blue LED still blinking causes data loss.
Wait until the blue LED is permanently illuminated before removing the product.

Product Damage
Installing or removing the product while power is applied damages the product. Before
removing the RTM from a powered system, power down the slot and the front blade’s
payload by opening the lower handle of the front blade and wait until the blue LED is
permanently ON.