Table 2-1, Environmental requirements, Hardware preparation and installation – Artesyn ARTM-9405 16x10GbE Installation and Use Guide (May 2014) User Manual
Page 16
Hardware Preparation and Installation
ARTM-9405 16x10GbE Installation and Use (6806800P45F)
16
environmental requirements specified below.
Operating temperatures refer to the temperature of the air circulating around the RTM, and
not to the component temperatures.
If you integrate the RTM in your own non-Artesyn system, contact your local sales
representative for further safety information.
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
+5 ºC (+41 °F) to +40 ºC (+104 °F)
(normal operation) according to
NEBS
Standard GR-63-CORE
-5 ºC (+23 °F) to +55 ºC (+131 °F)
(exceptional operation)
according to
NEBS Standard GR-63-CORE
-40 ºC (-40 °F) to +70 ºC (+158 °F)
(may be further limited by installed
accessories)
Airflow
The blade is designed to operate
in a
chassis that provides 35 CFM
across the
blade for the stated temperature
range.
-
Temp. change
+/- 0.5 ºC/min according to NEBS
Standard GR-63-CORE
+/- 0.5 ºC/min
Rel. humidity
5% to 90% non-condensing
according to
Artesyn-internal environmental
requirements
5% to 95% non-condensing
according to Artesyn-internal
environmental requirements
Vibration
1 g from 5 to 100 Hz and back to
5 Hz at
a rate of 0.1 octave/minute
5-20 Hz at 0.1 g2/Hz
20-200 Hz at -3.0 dB/octave
Random 20-200 Hz at -3 m/Sec2
Shock
Half-sine, 11 m/Sec, 30
mSec/sec2
Blade level packaging
Half-sine, 6 mSec at 180 m/Sec2