GPIB/RS-232 Programming

Sorensen SLM-4 Chassis

LOAD OFF Voltage

Purpose:
LOAD OFF voltage level query command.
Command Syntax:
SLM DC, SLD Modules: LDOF?{;|NL}
Description:
LDOF? returns the present load off voltage of SLD-series electronic load module.

LEVEL HIGH/LOW

Purpose:
Static mode's LEVEL low or high status query command or active LEVEL of AC electronic
load query command.

Command Syntax:

SLM Modules:

LEVE?{NL}

Description:
LEVE? returns the present level status, “0” indicates LEVEl LOW, and “1” indicates LEVEl
HIGH.

PRESET ON/OFF

Purpose:
PRESet ON or OFF status query command.
Command Syntax:
All Modules:

PRES?{NL}

Description:
PRES? returns the present preset status, “0” indicates PRESet OFF, and “1” indicates
PRESet ON.

MODE

Purpose:
CC, CR, CV or CP operating mode query command.
Command Syntax:
All Modules:

MODE?{NL}

Description:
MODE? returns the present operating mode status, ”0” indicates CC MODE, ”1” indicates
CR MODE, and “2” indicates CV MODE, “3” indicates CP MODE.
CV MODE is available DC electronic loads (except 500V models).
CP MODE is available in SLM DC electronic load modules.

NAME

Purpose:
Electronic Load module model number query command.
Command Syntax:
All Modules:

NAME?{NL}

Description:
NAME? return the active Electronic Load channel's model number.

4-22

M540069-01 Rev B