Sorensen SLM-4 Chassis

1.2 FEATURES AND FUNCTIONS

The SLM chassis provides high performance, easy operation and a cost-effective solution for
power source testing. The features of the SLM-4 electronic load chassis are:

• Plug-in design allows for easy replacement of different load modules as applications

change.

• Flexible configuration allows any bay to accept any SLM-(single module) or

SLD-(dual) series load module.

• Four analog programming inputs on the rear panel DB9 connector can control the

four SLM load modules' load current with arbitrary waveforms.

• Built-in GPIB/RS232 interface, which uses one GPIB address to control up to four

electronic load modules with set load status and read back meter capabilities.

1.3 SPECIFICATIONS

Specification details of the SLM-4 chassis are shown in Table 1–2.

LINE

100V/115V±10%

200V/230V±10%

FREQUENCY

50/60

HZ

AC INPUT

FUSE

T2A/250V (5x20mm) T1A/250V (5x20mm)

MAX. POWER
CONSUMPTION

100 W

DIMENSIONS (W*H*D)

17.3x7.0x17.5 in. (440 x177 x445 mm)

WEIGHT

NET : 20.9 lbs. (9.3 kg)

Table 1–2 SLM-4 Chassis Specifications

1.4 REGULATORY

COMPLIANCE

• Certified to UL 61010-1, CSA C22.2 No. 61010.1 and IEC/EN 61010-1

• CE Compliant:

o

Low Voltage Directive (73/23/EEC) using EN 61010-1, and

o

EMC Directive (89/336/EEC) using EN 61326

• FCC Compliant to 21 CFR, Subpart J.

1-2