beautypg.com

AMETEK SLM-4 User Manual

Page 38

background image

GPIB/RS-232 Programming

Sorensen SLM-4 Chassis

CLEAR status register

Purpose:
CLEar the PROT and ERR status byte registers.
Command Syntax:
All Modules:

CLER{NL}

Description:
CLER ; clear the PROT and ERR status byte register, the PROT and ERR status byte
register will indicate “0” after executing the CLER command.

STORE

Purpose:
STORE the load level and load status into the memory of the SL-series electronic LOAD.
Command Syntax:
SLM DC, SLD Modules: STOR{SP}{m[,n]}{;|NL}
SLM AC Modules:

STOR{SP}{m}{;|ML}

Description:
Parameter m is 1~5 for 5 different states withSL-series electronic load module's load status
and load current into the non-volatile memory.
Parameter n is 1-30 for 30 memory bank for 150 (m*n) different state with DC electronic load
module's load status and load current into the EEPROM memory in the electronic loads.
Example:

STORE 1; store the AC electronic load module's load status and load current into the
memory 1.
STORE 2,30; store the DC electronic load module's load status and load current into the
memory 147.

RECALL

Purpose:

Recall the state of load level and status, is stored by the GPIB/RS232 STORe command.
Command Syntax:
SLM DC, SLD Modules: REC{SP}{m[,n]}{;|NL}
SLM AC Modules:

REC{SP}{m}{;|NL}

Description:
This command is used to recall the memory state, is stored into memory by the GPIB/RS232
STORe command, up to 5 states can be recalled for AC electronic load modules, and up to
150 states can be recalled for DC electronic load modules.
Example:
REC 1; Recall the state of load level and status that is stored in memory 1 by GPIB/RS232
STOR command.
REC 147; Recall the state of load level and status that is stored in memory 147 by
GPIB/RS232 STOR command.

4-12

M540069-01 Rev B