beautypg.com

Section 5 maintenance, 1 periodic service, 2 fuse replacement – AMETEK CW-P User Manual

Page 61: Section 6 maintenance -1, 1 periodic service -1, 2 fuse replacement -1, Table 6–1 replacement fuses, Maintenance

background image

Operation Manual

5-1

SECTION 5

MAINTENANCE

5.1 Periodic Service

No routine maintenance on the CW Series unit is required, aside from periodic
cleaning.

Once a unit is removed from service, it may be cleaned with isopropyl alcohol (or an
equivalent solvent) on the metal surfaces, and a weak solution of soap and water on
the front panel.

Remove dust from in and around components on the printed circuit boards, taking
suitable measures to control electrostatic discharge (ESD).

5.2 Fuse Replacement

Replacement fuses for the CW Series supply are listed below in Table 6–1.

Ref. Designator Location

Rating

Manufacturer Mfr. P/N

Elgar P/N

F1, F2

Motherboard

25A, 250V, T

Bussmann

MDA-V-25 858-325-25

F3

Motherboard

1A, 250V, T

Bussmann
Littelfuse

C515-1A
230-001S

858-250-11
858-250-11

F4 (CW 801P,
CW 1251P)

Motherboard

10A, 600V DC Littelfuse

KLKD10

858-601-10

F4
(CW 2501P)

Motherboard

15A, 600V DC Littelfuse

KLKD15

858-601-15

Table 6–1 Replacement Fuses

CAUTION! Fuse replacement should be performed only by qualified
service personnel. Breaking the quality seal will invalidate the warranty.