Elgar CW-P Series

Specifications

Operation Manual

1-3

PHASE

Range

-359 to +359 degrees
Positive phase indicates time lag from reference

Accuracy

Within 100 microseconds of equivalent angle

Resolution

1 degree

1.2 Measurement

VOLTAGE

Range

0 to 270 VRMS; V–Option: 0 to 310 VRMS

Accuracy

±0.1% of range <100 Hz; ±0.2% of range

≥100Hz;

at >5 VRMS output; measured at point of remote sense

H-Option: ±0.3% of range >500 Hz

Resolution

0.1 VRMS

CURRENT*

Range

CW 801P

0 to 6.0 ARMS

CW 1251P

0 to 9.4 ARMS

CW 2501P

0 to 18.6 ARMS

Accuracy

±0.5% of range typical; for linear loads and
>0.12 ARMS for CW 801P, >0.19 ARMS for CW 1251P,
>0.37 ARMS for CW 2501P

H–Option/V–Option: ±0.75% of range and

≤500 Hz;

±1.0% of range and >500 Hz

Resolution

0.01 ARMS

PEAK INSTANTANEOUS CURRENT*

Range

CW 801P

0 to 25A

CW 1251P

0 to 35A

CW 2501P

0 to 70A

Accuracy

±2% of range typical; at >2% current range

Resolution

0.1A