beautypg.com

3 input, 3 input -5 – AMETEK CW-P User Manual

Page 19

background image

Elgar CW-P Series

Specifications

Operation Manual

1-5

POWER FACTOR*

Range

0 to 1

Accuracy

±4% of range for linear loads, typical; at >10% of power
range

Resolution

0.01

CREST FACTOR*

Range

0 to 3.5

Accuracy

±5% of range, typical; at 10% of RMS current range

Resolution

0.01

1.3 Input

VOLTAGE AND FREQUENCY

CW 801P

90 to 264 VRMS, 47 to 63 Hz, single-phase

CW 1251P

103 to 264 VRMS, 47 to 63 Hz, single-phase

CW 2501P

180 to 264 VRMS, 47 to 63 Hz, single-phase

CURRENT

CW 801P(–H)(–V)

13.5 ARMS, maximum at 90 VRMS

CW 1251P(–H)(–V)

17.7 ARMS , maximum at 103 VRMS

CW 2501P(–H)(–V)

19.7 ARMS , maximum at 180 VRMS

POWER FACTOR

>0.99 typical at full load nominal line

EFFICIENCY

>73% typical at full load

H–Option/V–Option at 1,000 Hz: CW 801P, >68% typical;
CW 1251P, >70% typical; CW 2501P, >72% typical


*Note: In a parallel system, the current/power displayed on the master unit is the sum
of all units in the system.