1.4 Protection

Overcurrent:

Shutdown mode
Accuracy: +/- 1% of full scale, for linear loads with current
>0.2 ARMS for CW 801P / CW 1251P, >0.4ARMS for CW 2501P

Over Voltage:

Accuracy: +/-2% of full scale
Range: 35-300 VAC; V–Option: 35-344 VAC

Over Temperature: Internal monitor

Isolation Range:

500 VRMS between either output terminal and chassis.

1.5 Rear Panel Connections

GPIB

RS-232

M/S OUT

M/S IN

ANALOG SLAVE

Power In and Power Out Terminal Strips (see Sections 3.5 and 3.6)

1.6 General

DIMENSIONS

CW 801P:

3.5" (89 mm) H x 19" (483 mm) W x 20.6" (524 mm) D

CW 1251P: 3.5" (89 mm) H x 19" (483 mm) W x 20.6" (524 mm) D

CW 2501P: 5.25" (133 mm) H x 19" (483 mm) W x 20.6" (524 mm) D

WEIGHT

CW 801P:

48 lbs. (22 kg)

CW 1251P: 53 lbs. (24 kg)