Elgar CW-P Series
Installation
Operation Manual
2-23
54. On the C slave CW press the ENTER/SAVE button.
55. Rotate the left knob until the left display reads “Addr”.
56. Rotate the right knob until the right display reads “1”.
57. Press the ENTER/SAVE button.
58. Press the ENTER/SAVE button.
59. Rotate the left knob until the left display reads “ChAn”.
60. Rotate the right knob until the right display reads “C”.
61. Press the ENTER/SAVE button.
62. Power down six CW power supplies.
63. Connect Elgar cable 890-497-40 between the A master “Analog Slave” and the
A slave “Analog Slave” connectors.
64. Connect Elgar cable 890-497-40 between the B master “Analog Slave” and the
B slave “Analog Slave” connectors.
65. Connect Elgar cable 890-497-40 between the C master “Analog Slave” and the
C slave “Analog Slave” connectors.
66. Connect up all of the daisy chained cables. The unit order is suggested below in
steps 67 through 71. As long as A master is the origin, all other daisy chained
units can be in any order.
67. Connect the Elgar cable 890-499-00 between the A master “M/S OUT” and the
A slave “M/S IN”.
68. Connect the Elgar cable 890-499-00 between the A slave “M/S OUT” and the
B master “M/S IN”.
69. Connect the Elgar cable 890-499-00 between the B master “M/S OUT” and the
B slave “M/S IN”.
70. Connect the Elgar cable 890-499-00 between the B slave “M/S OUT” and the
C master “M/S IN”.
71. Connect the Elgar cable 890-499-00 between the C master “M/S OUT” and the
C slave “M/S IN”.
72. Connect the load wiring as shown in Figure 3–12 above.
73. Power up six CW units simultaneously.
74. Control the master/slave array by controlling the CW A master via the front panel
or its command interface.