4.3.11 RMS Voltage Loop
This entry specifies whether the RMS voltage loop is on or off. When the voltage loop is
turned on, the RMS output voltage is tightly regulated at the sense point and the output
impedance is compensated for. When the voltage loop is off, the output impedance is
not compensated for.
LOOP
OFF/ON
4.3.12 Phase A Offset
This setting specifies the offset of the phase A output zero crossing in relation to the
externally applied phase–lock–loop signal in degrees.
CLPH
0..360
4.3.13 Phase B Offset
This setting specifies the offset of the phase B waveform in relation to the phase A
waveform in degrees.
PHB
0..360
4.3.14 Phase C Offset
This setting specifies the offset of the phase C waveform in relation to the phase A
waveform in degrees.
PHC
0..360
4.3.15 Slave Channel
Refer to Section 3.9, Master/Slave Configurations, for usage.
CHAN
A, B, or C
4.3.16 Slave Address
Refer to Section 3.9, Master/Slave Configurations, for usage.
ADDR
0..5
4.3.17 Slave Configuration
Refer to Section 3.9, Master/Slave Configurations, for usage.
CONF
A0A0–A0C5