beautypg.com

Parameter value range – Dukane 403-570-01 User Manual

Page 53

background image

Dukane Manual Part No. 403-570-01

Page 47

Section 5 - Touch Screen Menus

Screen

Parameter Name

Min.Value

Max.Value

Resolution

Units

SETUP>

PRE-WELD

TOOL Inertia

0

3000 (SVT012VR)
780 (SVT032VR)
160 (SVT042VR)

1

kg* cm²

TOOL Weight

0

25 .0

0 .1

kg

SPIN Decel .

25

200

1

%

TOP OF STROKE Position

0

140 .00

0 .01

mm

TRIGGER Position

1 .00

140 .00

0 .01

mm

Part Pickup Position

1 .00

140 .00

0 .01

mm

Part Pickup Thrust

1

100

1

%

Part Pickup Timeout

1

60

1

sec .

Pre-Spin Orientation

0

359 .9

0 .1

deg .

SETUP>

WELD

Weld Time/
Weld Rotations/
Weld Distance (Vertical) /
Energy

0 .01

50000

0 .01

sec ./

rev ./

mm/

Joules

VERT . Speed

.01

100 .00

0 .01

mm/s

SPIN RPM

5

750 (SVT012VR)
3000 (SVT032VR)
4000 (SVT042VR)

1

RPM

Weld Orientation

0

359 .9

0 .1

deg .

Trigger Torque

1

100

1

%

Torque Trigger Timeout

1

60

1

sec .

Constant Torque

1

100

1

%

Constant Torque Timeout

1

60

1

sec .

SETUP>

POST-WELD

Hold Speed

.01

100

0 .01

mm/s

Hold Move Time/
Hold Collapse

0

140 .00

0 .01

sec ./

mm

Hold Dwell Time

0

100 .00

0 .01

sec .

Hold Constant Thrust

1

100

1

%

TOOLS>

SYSTEM

SETUP

Home Offset

0

359 .9

0 .1

deg

Parameter Value Range

The minimum and maximum values of the welding
parameters are listed in Table 5-I.

Table 5–I

Welding Parameters