Dual Servo Spin Welder User’s Manual

Dukane Manual Part No. 403-570-01

Page 30

bad part means one or more of the measured parameters
was not within the limits set for the weld cycle. The

Time

and

Date

fields indicate the time and date the part

was welded.

Just below the

WELD

label, there are a number of fields

with weld data for the last cycle. The displayed data
lists the:

Time

- Weld time (seconds)

Rotations -

Number of spin motor rotations

during weld

Peak RPM -

Peak spin motor speed (RPM)

Peak Torque -

Peak spin motor torque (% of

maximum torque)

Energy -

Weld energy (Joules)

Orient . -

Welded part angular orientation

(degrees)

Weld End -

Weld end vertical position (mm)

Peak Thrust -

Peak vertical actuator thrust (% of

maximum thrust)

Hold End -

Hold end vertical position (mm)

Hold Col -

Hold collapse distance (mm)

Cycle -

Total cycle time (seconds)

VIEW PARTS

The

Part Data

button on the right side of the screen

displays seven part reports at a time. Each report
occupies two lines and displays the same information
reported on the

RUN

screen. The report starts with the

last cycle at the bottom and works backwards toward
the top. This is shown in Figure 5–3. The

Page Up

and

Page Down

buttons permit you to scroll through part

data one screen at a time, Press the

RUN

button to

return to the

RUN

screen.

Figure 5–3

VIEW PARTS Screen