Rotation method, Distance method – Dukane 403-570-01 User Manual
Page 41
Dukane Manual Part No. 403-570-01
Page 35
Section 5 - Touch Screen Menus
Rotation Method
In this method, the weld duration is controlled by
completing a specified number of spin revolutions. The
Weld Parameters
button is used to enter the settings
shown in Figure 5-13. The
Weld Rotations
field specifies
the number of weld revolutions. The actual number
of weld rotations as reported on the
RUN
screen after
the weld will be larger than the number entered in this
field and depends on the deceleration and whether final
orientation is enabled (see Orientation Option below).
The
VERT Speed (mm/s)
,
SPIN RPM
, and Dir. fields
are the same as in the Time Method. The
DONE
button
causes a return to the main
WELD
tab screen.
Distance Method
In this method, the weld duration is controlled by vertical
travel to a specified absolute or collapse distance. The
Weld Parameters
button is used to enter the settings
shown in Figure 5-14. The
Vertical (mm)
field specifies
the travel distance, depending on the position of the
Collapse / Absolute
switch located on the bottom of the
screen. If the switch selection is
Collapse
as shown in
Figure 5-14, the travel distance is measured relative to
the trigger point. If the switch selection is
Absolute
as
shown in Figure 5-15, the travel distance is measured
from the press topmost, or 0 position (also referred to
as the “home” position). The
Teach Position
button is
available in the Absolute Distance mode, which allows
the position to be defined by physically jogging the press
down to the desired weld end position. The layout of the
Teach Position screen is very similar to the
TRIGGER
Position screen shown in Figure 5-8. Directly below
the
Vertical (mm)
field is the minimum weld distance,
which is automatically calculated by the welder based
on other parameters such as speed and deceleration. The
VERT Speed (mm/s)
,
SPIN RPM
, and
Dir
. fields are the
same as in the Time Method. The
DONE
button causes
a return to the main
WELD
tab screen.
Figure 5–13
Weld Parameters Screen for Rotation
Method
Figure 5–15
Weld Parameters Screen for Distance
Method with Absolute Switch Selection
Figure 5–14
Weld Parameters Screen for Distance
Method with Collapse Switch Selection