beautypg.com

Dukane 403-570-01 User Manual

Page 50

background image

Dual Servo Spin Welder User’s Manual

Dukane Manual Part No. 403-570-01

Page 44

[.15 in.] above tooling contact, if possible) and press
the

Set Position

button. The stop block will be moved

up, and a flashing circle will appear next to the

DOWN

button when this process is complete, indicating that
the proximity switch is active. Press the

DONE

button

to return to the

SYSTEM SETUP

screen.

The

Data Export

button controls whether the weld

parameter data displayed on the

RUN

screen (Weld Time,

Rotations, etc.) is sent out to a computer connected to
the welder after each cycle (refer to Chapter 8). Pressing
the button toggles between

On

and

Off

states.

The

Graph Export

button controls whether the weld

profile data captured for the last weld is sent out to a
computer connected to the welder after each cycle
(refer to Chapter 8). This data includes the spin torque,
spin orientation, vertical thrust, vertical position, and
vertical speed. It is displayed in graphical format
in the Utility and can be exported to an ASCII file.
Pressing the button toggles between

On

and

Off

states.

The time required to transfer the data for this option
can be significant (several seconds, depending on weld
duration) and may adversely affect cycle rate as the
welder will not be ready to run another cycle until the
transfer is complete.

The

Start Type

button toggles from

Manual

to

Automatic

each time it is pressed. Manual is used for most
operations.

Automatic

is used in an automated

system and requires a switch closure contact on the User
I/O HD-15 connector (see Figure 3–9). A pinout of the
User I/O connector and automation wiring information
are provided in Appendix A.

Figure 5–34

Vertical Lower Limit Setup Screen

with Set Position Button