beautypg.com

Part tests – Dukane 403-570-01 User Manual

Page 46

background image

Dual Servo Spin Welder User’s Manual

Dukane Manual Part No. 403-570-01

Page 40

Part Tests

The Part Tests section is used to define limits for the
weld proocess and welder behavior for cases where the
process is outside the limits.

The

Process Limits

button is used to enter limits for

weld process results as shown in Figures 5-25, 5-26,
and 5-27. The following limits are available:

1.

Weld Time (s)

2.

Weld Rotations

3.

Orientation (Deg.)

4.

Weld Energy (J)

5.

Peak RPM

6.

Peak Torque (% of max.)

7.

Peak Thrust (% of max.)

8.

Cycle Time (s)

9.

Vertical Weld End (mm)

10. Hold Collapse (mm)

11.

Hold End Position (mm)

To enable a limit, press the

ON/OFF

box to the left of the

description and enter the

Lower

and

Upper

values. Any

combination of limits can be enabled simultaneously.
The

More Limits

… button shows additional limits, and

the

DONE

button causes the screen to return to the

POST-WELD

main menu.

Figure 5–25

Process Limit Definitions Screen 1 of 3

Figure 5–26

Process Limit Definitions Screen 2 of 3

Figure 5–27

Process Limit Definitions Screen 3 of 3