Part Tests
The Part Tests section is used to define limits for the
weld proocess and welder behavior for cases where the
process is outside the limits.
The
Process Limits
button is used to enter limits for
weld process results as shown in Figures 5-25, 5-26,
and 5-27. The following limits are available:
1.
Weld Time (s)
2.
Weld Rotations
3.
Orientation (Deg.)
4.
Weld Energy (J)
5.
Peak RPM
6.
Peak Torque (% of max.)
7.
Peak Thrust (% of max.)
8.
Cycle Time (s)
9.
Vertical Weld End (mm)
10. Hold Collapse (mm)
11.
Hold End Position (mm)
To enable a limit, press the
ON/OFF
box to the left of the
description and enter the
Lower
and
Upper
values. Any
combination of limits can be enabled simultaneously.
The
More Limits
… button shows additional limits, and
the
DONE
button causes the screen to return to the
POST-WELD
main menu.