The
Move To
button is used to rotate the tool to the value
displayed in the
Position (Deg .)
field. After pressing this
button, activate both RUN switches and wait for the
value in the Jog Pos. (Deg.) field to match the
Position
(Deg .)
value
WELD Setup
The
WELD
setup is the middle tab in the
SETUP
menu
and is shown in Figure 5-11. This screen contains the
weld
METHOD
selection (
Time, Rotation, Distance
, and
Energy
), a button for entering
Weld Parameters
, and
settings for several
OPTIONS
related to the weld phase
(
Orientation, Torque Trigger
, and
Constant Torque
).
Weld Method Selection
One of the available modes must be selected to perform
a weld. Regardless of the method, the weld is considered
to start at different points, depending on the
Torque
Trigger
option setting. If
Torque Trigger
is
OFF
, the
weld starts at the Trigger Position defined in the
PRE-
WELD
tab. If T
orque Trigger
is
ON
, the weld starts
when the desired spin torque threshold is exceeded (see
Torque Trigger Option below).
Time Method
In this method, the weld duration is controlled by time.
After choosing this method, the
Weld Parameters
button is used to enter the weld settings shown in
Figure 5-12. The
Weld Time
(s) entry specifies the weld
duration in seconds. Below this entry, a minimum weld
time value is displayed. This value corresponds to the
time needed for decelerating (i.e., slowing down and
stopping) the servo motors and is included as part of the
total weld time. The
VERT . Speed (mm/s)
sets the press
weld speed in millimeters per second. The
SPIN RPM
specifies the spin tool speed, which is constant during
the weld until the start of deceleration. The
Dir
. field
specifies the spin direction. The
DONE
button causes a
return to the main
WELD
tab screen.
Figure 5–11
WELD Main Setup Screen
Figure 5–12
Weld Parameters Screen for Time
Method