beautypg.com

Tools menu, Select setup tab, Utilities tab – Dukane 403-570-01 User Manual

Page 48

background image

Dual Servo Spin Welder User’s Manual

Dukane Manual Part No. 403-570-01

Page 4

TOOLS Menu

SELECT SETUP Tab

Pressing the

TOOLS

button displays the first tab

labeled

SELECT SETUP

. This contains eight buttons

for selecting a setup file as shown in Figure 5–29. The

Machine Cycle Count

in the lower right corner is the

total number of weld cycles that have occurred in the
machine’s lifetime.

UTILITIES Tab

The middle tab named

UTILITIES

and shown in

Figure 5–30 contains buttons for renaming, copying,
and erasing setups, as well as a button for accessing
a screen to record other machine settings and one for
exporting the graph data for the last weld.

Rename Setup

allows a name up to 26 characters. The

keypad has the letters

a

through

z

and a caps key for

A

through

Z

, plus the numbers

0

through

9

and a space

key. To rename a setup, enter a new name and then
press the

RENAME

button under the new name. Press

the

DONE

button when finished.

Copy Setup

copies the values of the currently loaded

setup file to the setup file specified. To copy a setup,
press the Destination Setup ID button, enter the desired
number, then press the

COPY

button. Press the

DONE

button when finished.

Erase Setup

clears all setup parameter values and

restores them to factory defaults. To erase a setup, press
the

ERASE

button, and then the

DONE

button.

The

OTHER MACHINE SETTINGS

button is used as a

“notepad” feature in recording the information shown
in Figure 5-31 and is provided as a convenience feature
for restoring the complete machine setup. The

Upper

Tool Nr .

and

Lower Tool Nr .

fields can be populated with

tool identification numbers. The

Column Position (mm)

Figure 5–30

UTILITIES Screen in TOOLS Menu

Figure 5–31

Record Other Machine Setetings

Screen in UTILITIES Menu

Figure 5–29

SELECT SETUP Screen in TOOLS Menu