Rounding, Equirement, Chapter 3 operation – Thor 1-4 HDMI to ATSC Modulators 8VSB User Manual

Page 11: H-4hdmi-atsc-ip

background image

H-4HDMI-ATSC-IP

Environment
Temperature

5~40℃(sustainable ),0~45℃(short time),

installing HVAC is recommended

Relative Humidity

20%~80% sustainable 10%~90% short time

Pressure

86~105KPa

Door & Window

Installing rubber strip for sealing door-gaps and dual level
glasses for window

Fire Protection

Fire alarm system and extinguisher

Power

Device power, HVAC and lighting should be independent to
each other. Device power requires AC 110V±10%, 50/60Hz or
AC 220V±10%, 50/60Hz. Please carefully check before
running.

2.5 Grounding Requirement

It is important to keep this device grounded to ensure all of the modules

function correctly. Correctly grounding the device will also help prevent any

electrical interference, lightening. Etc. Also it helps reject minor interference that

may disrupt the devices ability to function smoothly. General rule of them, make

sure the device is grounded when installing anywhere.

Always use copper wire. When applied correctly the ground must be wrapped

well to ensure maximum conduction so it can reduce any high frequencies. The

copper ground wire should also be as short and thick as possible

Installer must make sure that the two ends of the ground are well conducted

and have appropriate anti-rust properties.

It is prohibited to use any other device as part of the grounding electric

circuit.

The area of the conduction between the ground wire and device’s frame

should be no less than 25 ㎡.