Televes Serie H-60 User Manual
Page 154

154
General
4.- INPUT AND OUTPUT DESCRIPTIONS
4.1.- RF INPUT
RF Input is carried out through the connector (RF connector) in the top panel.
This connector can be easily replaced if deteriorated.
4.2.- USB PORT
The H60 has a USB port for data interchange with a PC.
- USB connector, type B -
The signals in this connector are as follows:
PIN no.
SIGNAL
CABLE
1
+5Vcc
Red
2
Data USB -
White
3
Data USB +
Green
4
GND (ground)
Black
The maximum signal level should in no case exceed 130 dbµV.
1
2
4
3
01031052_002_EN:103130_00.qxd 10/07/2013 8:01 Página 154