Televes Serie H-60 User Manual
Page 146

146
Analyzer
3.3.4.7.2.- VBW
This option allows one to modify the video filter. The unit automatically selects the most
appropriate one according to its mode.
To modify this parameter once the function has been activated, the current filter appears at the
bottom of the screen. Using the
allows one to browse through the different alternatives.
Confirmation of choice is done by pressing the
key.
The possible alternatives vary between 100Hz and 1 MH.
3.3.4.7.3.- ZOOM mode
This function allows one to see two spectrum traces on screen. At the top one can see the
current SPAN and on the bottom there is always a 20 MHz SPAN.
Pressing the Zoom Mode button brings up a contextual menu where one can
activate/deactivate this mode.
SPAN
Resolution filter
SPAN
Resolution filter
SPAN
Resolution filter
100 KHz 600 HzW (default filter)
300 HzW
1 KHz
5 MHz
800 KHzW
1.6 MHzW
3.2 MHzW
6.4 MHzW
200 MHz 3.2 MHz (default filter)
Other filters between
(200KHzW and 6.4MHzW)
200 KHz 2.4 KHzW (default filter)
1 KHzW
4.8 KHzW
500 MHz 3.2 MHz (default filter)
Other filters between
(200KHzW and 6.4MHzW)
500 KHz 9 KHzW (default filter)
4.8 KHzW
18 KHzW
10 MHz
800 KHzW (default filter)
Other filters between
(200KHzW and 6.4MHzW)
1.0 GHz
3.2 MHz (default filter)
Other filters between
(200KHzW and 6.4MHzW)
1 MHz
9 KHzW (default filter)
4.8 KHzW
18 KHzW
20 MHz
800 KHzW (default filter)
Other filters between
(200KHzW and 6.4MHzW)
1.5 GHz
3.2 MHz (default filter)
Other filters between
(200KHzW and 6.4MHzW)
2 MHz
36 KHzW (default filter)
18 KHzW
110 KHzW
50 MHz
800 KHzW (default filter)
Other filters between
(200KHzW and 6.4MHzW)
2.0 GHz
6.4 MHz (default filter)
Other filters between
(200 KHzW and 6.4MHzW)
5 MHz
200 KHzW (default filter)
300 KHzW
400 KHzW
100 MHz 3.2 MHz (default filter)
Other filters between
(200KHzW and 6.4MHzW)
SPAN
FULL
6.4 MHz (default filter)
Other filters between
(200 KHzW and 6.4MHzW)
01031052_002_EN:103130_00.qxd 10/07/2013 8:01 Página 146