Controller Module Setup

NOTE:
If K1 & K2 Safety Relays

are clear, blue or white,

you must use both

Safety Outputs 12-13

& 14-15 together. If K1

& K2 Safety Relays are

Green, you can use one

or both Safety Outputs.

1

Mute-Out Input LS4 (optional)

2

Remote Latch reset input

3

Mute-Out LS5 (optional)

4

Ground for Terminals

5

Cincinnati Interface + Input

6

Cincinnati Interface – Input

7

External relay monitor input

8

External relay monitor input

9

Aux relay K3 (N.O.) close when Green

Table 3: Controller Module Connection Chart (Lower Board)

10

Aux relay K3 (common)

11

Aux relay K3 (N.C.) close when Red

12-13

Safety Output #1 N.O. close when Green

14-15

Safety Output #2 N.O. close when Green

16

Case Ground (Earth)

17-18

Neutral (-) and Line (+)

alarm

Dry relay opens on fault or loss of power

Figure 5: Controller Module (Lower Board)