Installation procedures – Pinnacle Systems MG User Manual
Page 23

Controller Module Setup
NOTE:
If K1 & K2 Safety Relays
are clear, blue or white,
you must use both
Safety Outputs 12-13
& 14-15 together. If K1
& K2 Safety Relays are
Green, you can use one
or both Safety Outputs.
1
Mute-Out Input LS4 (optional)
2
Remote Latch reset input
3
Mute-Out LS5 (optional)
4
Ground for Terminals
5
Cincinnati Interface + Input
6
Cincinnati Interface – Input
7
External relay monitor input
8
External relay monitor input
9
Aux relay K3 (N.O.) close when Green
Table 3: Controller Module Connection Chart (Lower Board)
10
Aux relay K3 (common)
11
Aux relay K3 (N.C.) close when Red
12-13
Safety Output #1 N.O. close when Green
14-15
Safety Output #2 N.O. close when Green
16
Case Ground (Earth)
17-18
Neutral (-) and Line (+)
alarm
Dry relay opens on fault or loss of power
Figure 5: Controller Module (Lower Board)
Installation Procedures
Metal Box Controller Module
13