Depth Penetration Factor is the number used to

compute the distance the light curtain should be placed

from the point of operation (see Installation Procedures,

“ANSI Standard B11.19-2003”).

Diagnostics Display:

RDY

Keyswitch is in the lowest position (Floating

Blank is off).

FB

Indicates Floating Blank active and the

number of blocked beams.

OBST A second object found in the curtain (only

one obstruction is allowed to float).

5

Optional Features

Metal Box Controller Module

Emergency Stop Input(s)

Description: This option utilizes two normally-closed

emergency stop contacts to achieve a Catagory 4

safety level, per EN 954-1. If either or both emergency

stop contacts open, power to the safety output relays is

removed, causing the relays to de-energize and send

a stop signal to the guarded machine.
Application: This protects against a safety switch

contact failure or wiring fault. A contact failure or wiring

short will inhibit the system reset, causing the system’s

Diagnostic Message Display to indicate an Emergency

Stop Input Failure.
Usage: Wire one N.C. contact between Terminal #1 and

#4. Wire the second N.C. contact between Terminal #3

and #4 (located on power supply board). This option

cannot be used with Mute-Out. Alterative option: Wire

first N.C. contact between Terminal #6 and #4. Wire

second N.C. contact between Terminal #7 and #8. This

option cannot be used with Cincinnati or External relay

checking features. To reset ESTOP: Close both ESTOP

inputs, then use the latching relay reset input to clear

ESTOP fault (cycle closure between Terminal #2 and 4).

DeviceNet

Description: Optional external board that is mounted

to the door board inside the Metal Box Controller

Module. External board comes with its own directions.

Floating Blank

Description: On a press brake, the Floating Blank permits

the work piece to be placed in the guarded area and can

be moved around as long as it does not exceed the object

sensitivity selected.

A keyswitch by default allows for

zero, one, two, or three beams to be blocked anywhere

in the curtain as long as all the blocked beams are next

to each other. The customer may request different

blanking sizes for different applications. The Minimum

Object Sensitivity (MOS) and the Depth Penetration

Factor (DPF) change when the key switch position

is changed. The DPF is used to compute the safety

distance.
Location of the light curtain from the point of operation

must include the depth penetration factor D(pf)

equivalent to the beam spacing.
Minimum Object Sensitivity
indicates the minimum

size required to cause the light curtain to detect an

object even if it is moving (floating). If the obstruction is

slightly smaller (less than .25”) than the stated number,

the light curtain may blink RED/GREEN when the

object is moving in the field of view. If the obstruction

is smaller than the stated number by at least .25”, then

the light curtain will stay GREEN as long as there are

no additional obstructions.

Table 1a: .5” Beam Spacing Pylons

Inches/Millimeters Inches/Millimeters Inches/Millimeters

RDY (float off)

0.55” / 14mm 0.935” / 23.8mm 0.00” / 0.0mm

FB1 (1 beam float) 1.18” / 30mm 3.077” / 78.2mm 0.45” / 11.4mm

FB2 (2 beam float) 1.75” / 45mm 5.015”/129.2mm 0.95” / 24.1mm

FB3 (3 beam float) 2.36” / 60mm 7.089”/180.2mm 1.45” / 36.8mm

FB4 (4 beam float) 2.95” / 75mm 9.095”/231.2mm 1.95” / 49.5mm

FB5 (5 beam float) 3.54” / 90mm 11.101”/282.2mm 2.45” / 62.2mm

FB6 (6 beam float) 4.13” /105mm 13.107”/333.2mm 2.95” / 74.9mm

Display

Minimum

Object

Sensitivity, S

D(pf) Depth

Penetration

Factor

Max. Floating

object size

less than

Inches/Millimeters Inches/Millimeters

Inches/Millimeters

Rdy (float off)

1.18” / 30mm 3.077” / 78.2mm 0.00” / 0.0mm

FB1 (1 beam float) 2.36” / 60mm 7.089” /180.2mm 0.95” / 24.1mm

FB2 (2 beam float) 3.54” / 90mm 11.101” /282.2mm 1.95” / 49.5mm

FB3 (3 beam float) 4.72” / 120mm 15.113” /384.2mm 2.95” / 74.9mm

Display

D(pf) Depth

Penetration

Factor

Max. Floating

object size

less than

Table 1b: 1” Beam Spacing Pylons

Minimum

Object

Sensitivity, S

IMPORTANT: Place Floating Blank keyswitch

in lowest position and remove any obstructions

while aligning light curtain. Do not use Floating

Blank until light curtain is correctly aligned (see

Installation Procedure, “Alignment Procedures”).

The keyed selector switch is designated to be

supervisory controlled. After installation, the safety

key should be removed and controlled only by the

safety supervisor or authorized plant personnel.