Metal Box Controller Module

1

Input Power

18 to 33 VDC @ 10 W (optional)

90 to 140 VAC @ 12 W (standard)

128 to 240 VAC @ 12 W (optional)

All AC voltages work with 50 or 60 Hz

Fuses

AC power:

1 AMP Slow Blow (250VAC)

DC power:

1 AMP Fast Blow

Output Circuits (all isolated)

Terminals #12-13: N.O. (held closed when Green)

control reliable dry STOP circuit, wired through K1 &

K2 relays. 4A @ 120vac recommended max
Terminals #14-15: N.O. (held closed when Green)

control reliable dry STOP circuit, wired through K1 & K2

relays. 4A @ 120vac recommended max
Terminals #9-10-11: N.O. (held closed when

Green) – common – N.C. (held open when Green)

dry auxiliary circuit, wired through K3 relay.

4A @ 120vac recommended max
Alarm + - : N.O. (held closed when powered and NO

FAULTS) dry auxiliary circuit, wired through K4 relay.

4A @ 120vac recommended max

NOTE: For Older Control boxes prior to October 2007:

Both terminals #12-13 and #14-15 must be used to

achieve a control reliable STOP circuit. Newer control

boxes can use either or both sets of terminals.

Indicators

External:

OK/CLEAR

Green

BLOCK/FAULT

Red

AUTO/FLOAT ACTIVE

Yellow

SLAVE DISAGREEMENT

Red

The Diagnostics Display is a four-digit

alphanumeric with scroll

Internal:
+12V (RED) D2

CINN INT.

(GRN) D10

+5V

(YEL) D4

EXT RELAY

(GRN) D11

+5V

(YEL) D3

-5V

(GRN) D17

FAULT RELAY (GRN) D21

Construction:

Control Unit: All 18 Gauge painted steel

NEMA 12 lockable box with sealed front

panel and sealed cable entry fittings (8 lbs.).

Pylons: Heavy-duty aluminum extrusion

NEMA 4. Replaceable IR lens.

Sealed bulkhead positive locking circular

connectors. (Optional polycarbonate

protective tube guards).

Cables: Emitter 20’/ Receiver 8’ (supplied

standard). Shielded PVC 22 AWG cable

(optional cable lengths available).

Temperature Range 32° to 120° F

Dimensions

Controller Module: (see Dimensions)

Pylons: 1.45” (36.83mm) square (see

Dimensions)

Beam Spacing

.5” (12.7mm) standard

1” (25.4mm) (optional). The Floating Blank

option changes the effective beam spacing.

Minimum Object Sensitivity:

.5” (12.7mm) beam spacing is .55” (14mm)

1” (25.4mm) beam spacing is 1.18” (30mm)

Response Time < 30 mSec total

Scanning Frequency 5.9 KHz

Shock Tested to withstand high vibration applications.

Self-Checking every 20 milliseconds

Scanning Distance All units are supplied standard

with a 20’ (6.1m) scanning capability. Extended

range units are available and must be specified -- 50’

maximum (15.2m).

Maximum Operating Distance Stated as last two

digits in model number.