Revtrak operation operating procedures – Pengo RevTrak User Manual
Page 20

20
PENGO RevTrak Manual
REvTRAK OPERATION
OPERATING PROCEDURES
SD CARD PREPARATION
. Ensure Display unit and Logger have power. Power
can be supplied by either the prime movers battery or
by connecting into the auxiliary port located inside the
prime movers cab. The display should be visible as
well as green lights on the logger.
2. Open the top lid of the Logger to install SD card.
Do
not open lid by force! See figure 1E
3. Install the provided SD card into the Logger. The
Logger will not record unless a SD card is installed.
The SD card will only install into the Logger one way,
refer to the arrow on the SD card.
3-A. The SD card must be pre loaded with the file
CONFIG.CFG. The SD card provided with the RevTrak
system comes pre loaded with the CONFIG.CFG file. If
additional SD cards are used with the RevTrak system
this configuration file
MUST be loaded on the SD card
before use.
Use 2GB SD cards only.
3-B. It is important, that the SD card file format is
FAT.
This format is the only format the logger will recognise.
If you encounter an error with the SD card it could be
the file format.
wARNING
Before operating, always ensure that
all electrical connections are tight and
free from potential hazards and or
entanglement during operation.
Figure E
DISPLAY LOCATION / INTERFACE
. Chose a convenient location to mount the RevTrak
display. The location should not interfere with safety
devices (lap bar) or compromise the operators visibility.
The location should also allow the operator to easily access
the display to start and stop the data recording function.
-A. The display can be mounted to a glass surface using
the two suction cups provided with the RevTrak. (See
figure 1A for suction cup installation) When using the
suction cups be sure to lightly moisten the cups for better
suction against the glass.
-B. The display can also be hard mounted to any surface
using hardware (not included). This method is only
recommended if the location is to be permanent.
DATA RECORDING OPERATION
. Select the Drive model by pressing the MDL button.
This will bring up the model selection screen. This screen
will allow the operator to select from the different models
of Pengo Revolution Series Anchor Drives.
Note, Ensure the correct Drive model is
selected. The RevTrak system does not automatically
select the model. This is set by the operator.
To select, turn the dial to scroll through the different models
and push in the dial to select the desired model. Once the
desired model is selected push the ESC button to return
to the main display screen.
2. To start recording the installation data the operator must
push the button on the display located directly under the
“REC” on the display. (When the “REC” button is pressed
the logger will start recording the torque, differential
pressure, date, time and Drive model)
3. When the “REC” button is pressed the word “Recording”
will appear below the numerical torque value. When the
“REC” button is pressed for a second time the logger will
stop recording data and the word “RECORDING” will no
longer be displayed.
Note: It is recommended that when recording data the operator start and stop the recording with each
anchor / pier. Allowing the RevTrak system to continuously record for extended periods of time will make
interpreting the exported data difficult.
NOTE: The system must be powered on and then powered off on the first
time of use. This will set the system and all components. This step is only
necessary on the first time of use.