Revtrak display set-up, 0 pengo revtrak manual, Figure a figure 2a figure 3a – Pengo RevTrak User Manual
Page 10

0
PENGO RevTrak Manual
REvTRAK DISPLAY SET-UP
Fasten suction cups (3) to bracket () using nut
(19). See figure 1A.
Only complete this step if the Display unit will be
mounted on a glass surface. Suction cups are not
required for all mounting situations. Bracket can
also be mounted using hardware (not provided).
1
Fasten logger clip (9) to bracket () using screw
(14) and nut (15). See figure 2A.
2
Secure display (1) to bracket (11) by first installing
four screws (4) to the back side of the display. Do
not tighten screw completely. Slide the bracket
over the screws, slide bracket up and tighten screws.
See figure 3A.
3
Figure A
Figure 2A
Figure 3A
TOLERANCES UNLESS OTHERWISE SPECIFIED
.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.
LBS
Kg
0.00
Figure 1A
THIS DRAWING IS THE PROPERTY OF PENGO 500 E.
HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL
BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS
SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS
BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS
HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID
PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.
NO PART OF THIS DRAWING SHALL BE COPPIED OR
DUPLICATED OR IT'S CONTENTS DISCLOSED.
DRAWN BY
MATERIAL
TITLE:
SIZE
REV
SCALE: 1:2
SHEET 1 OF 1
HEAT TREAT
THIRD ANGLE PROJECTION
B
DATE
CHECKED BY
TOLERANCES UNLESS OTHERWISE SPECIFIED
.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.
LBS
Kg
0.00
Figure 2A
THIS DRAWING IS THE PROPERTY OF PENGO 500 E.
HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL
BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS
SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS
BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS
HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID
PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.
NO PART OF THIS DRAWING SHALL BE COPPIED OR
DUPLICATED OR IT'S CONTENTS DISCLOSED.
DRAWN BY
MATERIAL
TITLE:
SIZE
REV
SCALE: 1:2
SHEET 1 OF 1
HEAT TREAT
THIRD ANGLE PROJECTION
B
DATE
CHECKED BY
3
3
9
9
4
5
TOLERANCES UNLESS OTHERWISE SPECIFIED
.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.
LBS
Kg
0.00
Figure 3A
THIS DRAWING IS THE PROPERTY OF PENGO 500 E.
HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL
BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS
SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS
BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS
HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID
PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.
NO PART OF THIS DRAWING SHALL BE COPPIED OR
DUPLICATED OR IT'S CONTENTS DISCLOSED.
DRAWN BY
MATERIAL
TITLE:
SIZE
REV
SCALE: 1:4
SHEET 1 OF 1
HEAT TREAT
THIRD ANGLE PROJECTION
B
DATE
CHECKED BY
4