2 pengo revtrak manual, Figure b figure 2b figure 3b – Pengo RevTrak User Manual
Page 12
![background image](https://www.manualsdir.com/files/769947/content/doc012.png)
2
PENGO RevTrak Manual
ANChOR DRIvE SET-UP (RS-7 & RS-7X SINGLE SPEED MODELS)
Remove bail housing (if equipped) to expose hydraulic motor.
Note: before removing the bail housing scribe a line from the housing to the gearbox to indicate a reference mark
for re-assembly.
1
Remove the steel plug caps from the adapters
located on the top of the hydraulic motor block.
Once the caps have been removed install two
transducers (6) as shown in figure 1B.
Note: use of Teflon tape on the threads of the transducers
is highly recommended to reduce potential leaks.
2
Secure wire harness (4) to the transducers (6).
Clip harness end marked
“Pressure” to the
pressure side transducer and the harness end
labeled
“Tank” to the Tank side transducer. Reference
the decal on the block to determine the correct port. See
figure 2B.
Note: the harness end labeled “Sequence” will not be used
on single speed units.
3
Fasten controller (3) to the mounting bracket as
shown in figure 3B with bolts (17) and nuts (18).
4
NOTE: The following instruction steps are for PENGO RS series Drives only.
Figure B
Figure 2B
Figure 3B
TOLERANCES UNLESS OTHERWISE SPECIFIED
.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.
LBS
Kg
0.00
Figure 1B
THIS DRAWING IS THE PROPERTY OF PENGO 500 E.
HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL
BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS
SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS
BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS
HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID
PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.
NO PART OF THIS DRAWING SHALL BE COPPIED OR
DUPLICATED OR IT'S CONTENTS DISCLOSED.
DRAWN BY
MATERIAL
TITLE:
SIZE
REV
SCALE: 1:4
SHEET 1 OF 1
HEAT TREAT
THIRD ANGLE PROJECTION
B
DATE
CHECKED BY
6
6
TOLERANCES UNLESS OTHERWISE SPECIFIED
.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.
LBS
Kg
0.00
Figure 2B
THIS DRAWING IS THE PROPERTY OF PENGO 500 E.
HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL
BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS
SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS
BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS
HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID
PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.
NO PART OF THIS DRAWING SHALL BE COPPIED OR
DUPLICATED OR IT'S CONTENTS DISCLOSED.
DRAWN BY
MATERIAL
TITLE:
SIZE
REV
SCALE: 1:8
SHEET 1 OF 1
HEAT TREAT
THIRD ANGLE PROJECTION
B
DATE
CHECKED BY
6
6
4
TOLERANCES UNLESS OTHERWISE SPECIFIED
.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.
LBS
Kg
0.00
Figure 3B Rev A
THIS DRAWING IS THE PROPERTY OF PENGO 500 E.
HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL
BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS
SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS
BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS
HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID
PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.
NO PART OF THIS DRAWING SHALL BE COPPIED OR
DUPLICATED OR IT'S CONTENTS DISCLOSED.
DRAWN BY
MATERIAL
TITLE:
SIZE
REV
SCALE: 1:8
SHEET 1 OF 1
HEAT TREAT
THIRD ANGLE PROJECTION
B
DATE
CHECKED BY
3
7
8
7
Pressure
Tank