DIO w/ 2.5kv isolated:
4x Digital Input (Source type)
– Input Voltage (Dry Contact): Logic 0: Close to GND
– Logic 1: Open
– Input Voltage: Logic 0: 3V max
– Logic 1: +5V ~ +30V
4x Digital Output (Sink type)
– Output Voltage: 3.6V ~ 5V
– Sink current: 200 mA max. per channel
▪ GPIO: 2x digital in / 2x digital out
▪ COM #1: RS232/422/485 w/ 2.5kv isolated
▪ COM #2: RS232/422/485 w/ 2.5kv isolated
▪ COM #3: RS232 w/ RI or 5V selection
▪ COM #4: RS232 w/ RI or 12V selection
Audio
▪ AC97 codec: Realtek ALC886-GR
▪ Audio interface: Line out/Line in/MIC-in Audio Jack
Ethernet
▪ LAN chip: dual Intel® 82574L Gigabit LAN
▪ Ethernet interface: 10/100/1000 Based-Tx Ethernet compatible
Mechanical & Environment
▪ Color: pantone black\RAL 15 00 front bezel w/ Pantone 400C\RAL
090 80 10 metal style membrane
▪ IP protection: IP65 front
▪ Mounting: panel/ wall/ stand/ VESA 100mm x 100mm
▪ Power input: 12V~ 30V DC
▪ Power adapter: Optional AC to DC power adaptor (+12V, 60W)
▪ Vibration:
– IEC 68 2-64 (w/ HDD)
– 1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating)
– 2Grms @ sine, 5~500Hz, 1hr/axis (CFast Operating)
– 2.2Grms @ random condition, 5~500Hz, 0.5hr/axis (Non-operating)
▪ Shock:
– IEC 68 2-27
– HDD: 20G@wall mount, half sine, 11ms
▪ Operating temperature: -5°C to 60°C
▪ Storage temperature: -20°C to 75°C
▪ Operating humidity: 10%~90% relative humidity, non-condensing
Limits to be at 90% RH at max 50°C
▪ Dimension: 317 x 243 x 65.89mm
▪ Weight: 3.9 Kg
Certifications
▪ CE approval
▪ FCC Class A