Appendix d: power consumption, Power consumption management – NEXCOM APPC 1230T User Manual
Page 128
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
112
APPC 1230T/1231T/1235T/1530T/1531T/1730T/1731T/1930T/1931T User Manual
Appendix D: Power Consumption
Appendix D: Power Consumption
Power Consumption Management
Purpose
The purpose of the power consumption test is to verify the power dissipation
of the system and the load of the power supply.
Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver:2.0
Device Under Test
DUT: sys#1/
Test Procedure
1. Power up DUT and then boot Windows 7.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.
+12V
+24V
+30V
Full-Loading Mode
3.2A
1.65A
1.26A
Total
38.4W
39.6W
37.8W
Standby Mode
0.75A
0.41A
0.36A
Total
9W
9.84W
10.8W
APPC 1930T/1931T
+12V
+24V
+30V
Full-Loading Mode
4.2A
2A
1.63A
Total
50.4W
48W
48.9W
Standby Mode
0.74A
0.41A
0.34A
Total
8.88W
9.84W
10.2W
APPC 1730T/1731T