NEXCOM NISE 101 User Manual
Page 64
Copyright © 2010 NEXCOM International Co., Ltd. All Rights Reserved.
51
NISE 101 User Manual
Chapter 4: BIOS Setup
Resume By Alarm
Enabled
When Enabled, you can set the date and time you would like the
Soft Power Down (Soft-Off) PC to power-on in the “Date (of Month)
Alarm” and “Time (hh:mm:ss) Alarm” fields. However, if the system
is being accessed by incoming calls or the network (Resume On Ring/
LAN) prior to the date and time set in these fields, the system will
give priority to the incoming calls or network.
Disabled
Disables the automatic power-on function. (default)
Date (of Month) Alarm
0
The system will power-on everyday according to the time set in the
“Time (hh:mm:ss) Alarm” field.
1-31
Select a date you would like the system to power-on. The system
will power-on on the set date, and time set in the “Time (hh:mm:ss)
Alarm” field.
Time (hh:mm:ss) Alarm
This is used to set the time you would like the system to power-on. If you
want the system to power-on everyday as set in the “Date (of Month)
Alarm” field, the time set in this field must be later than the time of the
RTC set in the Standard CMOS Features submenu.