Link manager, links of function blocks – KLING & FREITAG K&F CD Remote User Manual
Page 35

User's manual
K&F CD 44 Remote
KLING & FREITAG GMBH © 2014
Version 5.5
Page 35 of 50
0
2
4
6
8
10
12
14
100
1000
10000
100000
Diss
Filter
Parameters: 4°, 40%, 120m
-3 dB compensation point: 4973 Hz, maximum compensation deviation: 0.24 dB
0
2
4
6
8
10
12
14
100
1000
10000
100000
Diss
Filter
Parameters: -4°, 40%, 120m
-3dB compensation point: 8160 Hz, maximum compensation deviation: 0.34 dB
0
2
4
6
8
10
12
14
100
1000
10000
100000
Diss
Filter
Parameters: -4°, 30%, 120m
-3 dB compensation point: 16068 Hz, maximum compensation deviation: 1.5
15. Link manager, links of function blocks
For easier operating, the individual function blocks can be linked and are thus placed into a
Master – Slave relationship. The operating element that takes over the controls is called the
Master, and the operating elements that are controlled by the Master are called Slaves.
Aside from connecting Function Blocks within one controller, Function Blocks can also link
between different devices.
The following can be linked:
1.
Graphic Equalizers (CD 44 only)
2.
Input Gains
3.
Input Delay (CD 44 only)
4.
Limit Reduction
5.
Output Gain