KBC Networks WESII User Manual
Page 132

WESII User Manual
 
 
Manual-WESII-Rev1403 
Copyright © KBC Networks 2014 
Page 131 of 140
www.kbcnetworks.com
Setting the Client frequency: 
 
The Client obtains its frequency from its connected Host/AP. To ensure that a particular 
Client connects to a certain Host/AP, the SSID, Country Code and Channel Width settings 
need to be the same as the Host/AP unit to which the unit wishes to connect to. On the 
Client unit, in the Basic Wireless: Radio 1 menu option, ensure that the Remote AP-Lock 
to Client is ticked. Click on 
you wish to connect to. This will now be shown in the box next to the 
The units will now connected on the designated frequency – this may take a few 
minutes. 
 
Interference Analyzer: The interference Analyzer facility is located on the Host/AP unit 
and can be used to determine whether there are other pieces of equipment in the vicinity 
using the same frequencies as the WESII units use. By carrying out an interference 
analyzer survey, congested channels can be avoided when selecting channels manually. 
 
Note:
Surveys to detect interference should only be conducted when directly connected
to the Host/AP, if connected to the Host/AP via the Client over the wireless link, the link 
will be disconnected. 
 
To carry out a frequency site survey select 
Analyzer is only found on the Host/AP unit and only available if a channel width of either 
20M or 20/40MHz is selected. 
 