Tally (GPO) setup



For many installations, Tally (GPO) outputs are necessary to remote control external devices or to signal
conditions such as On Air. from HW revision 4 of the base unit, the physical outputs are relay contacts (see
pin assignment and electrical specs).

The MIX4 has 8 Hardware Tally (GPO) outputs - HTally 01 to HTally 08

There are 8 rows in this pane for Hardware Tally setup. HTally 01 is typical of the 8 in the hardware group.

Here will be distinguished whether it will be a static signal NC (normally closed) / NO (normally open)
or if it is a 100ms pulse

Signal Type

Static + / Staic -

NC / NO

Start + / Start -

100ms puls NO / 100ms puls NC

Stop + / Stop -

100ms puls NO / 100ms puls NC


For each Tally one of the predefined types can be selected :

Tally Type

OFF
FaderStart
ButtonStart
Event
Hybrid
Button+FaderStart


Finally the triggering source (related to one of the MIX4 inputs) or the triggering event must be selected :

Event

On Air
Talkback
Lim A, B, C, D, Lim All
USERx button
BUSx button