10 dvb-t2 modulation settings – DekTec DTC-300 StreamXpress User Manual
Page 37

DTC-300-SP – StreamXpress
USER MANUAL
37
In DVB-T transmission, it is advantageous to know from which cell the signal is coming from to allow
switching between cells when receiving the signal on a mobile device. The StreamXpress can set the
TPS bits S40 to S47 as a cell identifier. To enable this setting, tick on the box.
#9 Cell Identifier:
This field represents the Cell Identifier value that is written in the bit S40 to S47 of the TPS. The value
is from 0 to 65635.
3.5.10 DVB-T2 Modulation settings
If the DekTec adaptor is licensed to support the DVB-T2 modulation, the user can select the DVB-T2
modulation and change its parameters.
DVB-T2 is the standard used for advanced Terrestrial broadcast where DVB has been adopted.
There are lots of parameters for DVB-T2 so most of the parameters are set under Params.
NOTE: StreamXpress offers only single PLP (Physical Layer Pipe) MPEG-2 TS playout. To generate
multi PLP, please use the T2Xpress that can be licensed on most of DekTec UHF/VHF modulators.
Variable
Type
Description
Details Diag
Params
Button
Select this to change the DVB-T2 modulation parameters
1
The DVB-T2 modulation parameters are organized in 5 sections:
1-General Parameters
2-PLP #0
3-Frame Structure
4-FEF (Future Extension Frames)
5-Message center and pre-set configurations
1