User controls – Optoma EH415e User Manual
Page 63
62
User Controls
3. Select “Turn Windows features on or off” to open.
4. Have “Telnet Client” option checked, then press “OK” button.
Specsheet for “RS232 by TELNET” :
1. Telnet: TCP.
2. Telnet port: 23 (for more detail, kindly please get contact with the
service agent or team).
3. Telnet utility: Windows “TELNET.exe” (console mode).
4. Disconnection for RS232-by-Telnet control normally: Close
Windows Telnet utility directly after TELNET connection ready.
Limitation 1 for Telnet-Control: there is less than 50 bytes for
successive network payload for Telnet-Control application.
Limitation 2 for Telnet-Control: there is less than 26 bytes for one
complete RS232 command for Telnet-Control.
Limitation 3 for Telnet-Control: Minimum delay for next RS232
command must be more than 200 (ms).
(*, In Windows XP built-in “TELNET.exe” utility, “Enter” key
pressed will have “Carriage-Return” and “New-Line” code.)