Installation (continued...), 4 electrical connections, Wire color may be white or yellow – Nexen TM340 912751 User Manual

Page 9

background image

6

FORM NO. L21279-B-0513

FIGURE 3.10 TM310T Wiring Diagram

FIGURE 3.11 TM340 Wiring Diagram

3.4 ELECTRICAL CONNECTIONS

3. INSTALLATION (continued...)

D—

COM

D+

8

7

RS485

(D-)

White

Black

Red

Black

Red

White

Green

Black

Red

White

White

Red

Black

Green

Green

Red

Black

Black

Red

Green

+

A

COM

RS485

(D+)

Alarm Common

Maximum or unbalanced load alarm

Minimum alarm

COM

TOTAL

 0∼10V

No.2

 0∼5V

No.1

 0∼5V

(supplied by the user)

 0∼1mA

COM

20

19

18

17

3

9

10

11
12
13
14
15
16

6

5

4

2

1

1
2

4

5
6
7
8

3

3

6

5

4

2

1

1
2

4

3

5

Green

Black

Red

White

6

Black

White

White

White

Red

Green

5

3
4

2

1

SW

sensor

TSA

sensor

SW

sensor

TSA

sensor

TSA

sensor

MB

sensor

MB

sensor

MB

sensor

Two TSA Sensors

Two MB Sensors

One TSA Sensor

One MB Sensor

Two SW Sensors

+24V

0V

24VDC

GND

earth

earth

L

N

Power

Connection

TM340-AC

TM340-DC

100~240VAC

50/60Hz

(Components supplied by the user)

Terminals marked with an asterisk (*) cannot be

used in combination. Do not connect anything

to the terminals that are not being used.

Meter
Output

Indicator
Output

Control
Output

Alarm
Output

RS485
Communication

*

*

*

Wire color may be white or yellow.

1
2

11

10

5
9

9

Black

Red

White

Green

5

3
4

2

1

(Components supplied by the user)

1
2

4

5
6
7
8
9

3

9

10

1

1

1

1

10

9

3

9

8

7

6

5

4

2

1

1
2

4

5
6
7
8
9

20

19

18

17

16

15

14

13

12

3

21

22
23

9

24
25

9

4~20mA*
0~10V*

COM

0~1mA

(user supplied)
No.1 0~5V
No.2 0~5V
TOTAL 0~10V

COM

Minimum alarm
Maximum or unbalanced load alarm

Alarm Common

RS485 (+D)

COM

A

+

Green

White

White

Red
Black

Black

Red

Green

Green
Black
Red
White

White

Red

Black

Green

White

Red
Black

Red

Black

White

26

RS485(-D)

10
11

Green
Black
Red
White

SW

sensor

SW

sensor

TSA

sensor

TSA

sensor

TSA

sensor

MB

sensor

MB

sensor

MB

sensor

+24V

0V
FG

24VDC

GND

D-type earth

D-type earth

L

N

Power

Connection

TM310T-AC

TM310T-DC

100~240VAC

50/60Hz

FG

Terminals marked with an asterisk (*) cannot be

used in combination. Do not connect anything

to the terminals that are not being used.

Two TSA Sensors

Two MB Sensors

One TSA Sensor

One MB Sensor

Two SW Sensors

RS485
Communication

Meter
Output

Control
Output

Indicator
Output

Alarm
Output

*

Wire color may be white or yellow.