10 Motion Generator: Features and Functions

Page 50

User Manual for PMotion

10.2

Summary of Segment Constraints

Segment Type

Segment start constraints

0: Constant Position

P

matched

V A J

not specified

1: Constant Velocity

P

matched

V

matched or specified

,

A J

not specified

2: Constant Acceleration
3: Sine-Squared Velocity
4: Cycloidal
5: Modified Trapezoidal
6: Modified Sine
7: Triple Harmonic
8: Sinusoidal
10: Ramp
11: Throw
14: Sine-Constant-Cosine
15: Simple Harmonic

P

matched

V

matched or not specified

A J

not specified

9: Polynomial

P

matched

V A J

matched or specified or not specified

12: Quadratic Spline

P V

matched

A J

not specified

13: Cubic Spline

P V A

matched

J

not specified

Legend:

P: Position

V: Velocity

A: Acceleration

J: Jerk

Matched means that the derivative value doesn’t change from the

end of one segment to the beginning of the next (matched with previous).

Specified means that the derivative value can be set at that point

on the segment (value as specified).

Not specified means that the derivative value cannot be altered at that point of the

segment (no value specified).