Monitoring Drive Status

The color of the drives in the Status window indicates the status of the drives.

Color

State

Definition

Resolution

Green

Normal

Drive is active.

N/A

Red

Needs rebuild

Drive has failed.

Replace the failed
drive.

Gray or Red

Unplugged

Drive is offline.

Verify that the drive is

Background will turn

inserted. Replace if

red after a write to

necessary.

the volume.

Light Blue

New drive

New drive.

N/A

Yellow

Rebuilding

Drive is being rebuilt.

N/A

Purple

Wrong slot

There is a mismatch be-

Install the correct drive

tween Serial # and ex-

into the bay.

pected Serial #. Drive
is in the wrong bay.