beautypg.com

StorCase Technology InfoStation 5-Bay SATA 3Gbps RAID User Manual

Page 52

background image

42

RAID Configuration

StorCase Technology, Inc.

InfoStation 5-Bay RAID User's Guide - Rev. C00

2.

Select one of the following policy options:

Manual Rebuild -

Requires the user to manually initiate a rebuild of
the volume

Automatic Rebuild -

Forces the Daemon to initiate the rebuild process
automatically and minimize the possibility of data
loss

3.

If Automatic Rebuild is selected, the user will have the following additional choi-
ces:

Immediate Rebuild -

Causes the Daemon to rebuild immediately follow-
ing detection of an offline drive

Rebuild Only If Needed -

Delays the rebuild of a SAFE volume with an offline
drive until the write occurs to the SAFE volume

4.

Click Accept to implement selected options.

The Daemon will use the specified rebuild policy to maintain redundancy. The Sta-
tus window will display a rebuild in process.

Figure 13: Policy Specification