DE200i-SW/SWC User's Guide - Rev. C01

StorCase Technology Inc.

Appendix B - Factory-Installed Options

23

4. After a short length of time the unit display will turn from a flashing unit ID number to

a steady “u”, indicating that the device is powered down, unlocked and ready to be

removed from the receiving frame.

NOTE:

The timer for device spin down is controlled by a small selector, located in a cutout

on the side of the DE200 receiving frame as shown in Figure 11. When the key is

turned to the OFF position, and when the timer receives a No SCSI Activity signal

from the Hot Swap Board, it waits the specified delay time before displaying a “u”

on the front panel of the receiving frame. The amount of time required for a drive

to spin down is approximately 15 seconds or more. This number can vary

depending on the type of SCSI device and manufacturer (some drives may require

45 seconds or more). The factory configuration is set for 20 seconds. A different

delay time may be selected with the provided alignment tool. Refer to the SCSI

device manufacturer’s manual for more information on required device spin down

time.

Carrier Installation

Follow the procedures below to install the DE200 Carrier into the receiving frame equipped

with the Hot Swap option.

1. Install the carrier into the receiving frame. A "u" will be present on the front panel,

indicating that the carrier is in an unlocked condition.

2. Turn the key lock mechanism, located on the front of the receiving frame, counter

clockwise to the ON position. This locks the drive into the receiving frame and activates

the Hot Swap Board. The drive will begin to spin up and the unit ID number on the display

will begin flashing.

3. After a short length of time the unit display will stop flashing, indicating that the device

is ready to be used.