beautypg.com

Adjusting the spin down/up timer – StorCase Technology DE200i-SWC User Manual

Page 22

background image

DE200i-SW/SWC User's Guide - Rev. C01

StorCase Technology, Inc.

Installation

15

Figure 11: Device Spin Down/Up Timer Switch

Adjusting the Spin Down/Up Timer

The timer for device spin down is controlled by a small selector, located in a cutout on the side

of the DE200 receiving frame as shown in Figure 11. When the key is turned to the OFF position,

and when the timer receives a NO SCSI Activity signal from the Isolator Board, it waits the

specified delay time before displaying a “u” on the front panel of the receiving frame. The

amount of time required for a disk drive to spin down is approximately 15 seconds or more.

This number can vary depending on the type of SCSI device and manufacturer (e.g. a Seagate

Barracuda may require 45 seconds). The factory configuration is set for 20 seconds. A

different delay time may be selected with the provided alignment tool. Refer to the SCSI device

manufacturer’s manual for more information on required device spin down time.

Front of

Receiving

Frame

0143

0 2

4

6

8

A

C

E

0 = 10 SECONDS

8 = 50 SECONDS

1 = 15 SECONDS

9 = 55 SECONDS

2 = 20 SECONDS

A = 60 SECONDS

3 = 25 SECONDS

B = 65 SECONDS

4 = 30 SECONDS

C = 70 SECONDS

5 = 35 SECONDS

D = 75 SECONDS

6 = 40 SECONDS

E = 80 SECONDS

7 = 45 SECONDS

F = 85 SECONDS

Spin Down/Up Time

This manual is related to the following products: