Installation

Adjusting the Spin Down/Up Timer

NOTE:

The timer for device spin down is controlled by a small selector, located in a cutout

on the side of the DE200 receiving frame as shown in Figure 11. The amount of

time required for a drive to spin down is approximately 15 seconds or more. This

number can vary depending on the type of SCSI device and manufacturer (some

drives may require 45 seconds or more). The factory configuration is set for 20

seconds. A different delay time may be selected with the provided alignment tool.

Refer to the SCSI device manufacturer’s manual for more information on required

device spin down time.

Figure 11: Device Spin Down/Up Timer Switch

Front of

Receiving

Frame

0143

0 2

4

6

8

A

C

E

0 = 10 SECONDS

8 = 50 SECONDS

1 = 15 SECONDS

9 = 55 SECONDS

2 = 20 SECONDS

A = 60 SECONDS

3 = 25 SECONDS

B = 65 SECONDS

4 = 30 SECONDS

C = 70 SECONDS

5 = 35 SECONDS

D = 75 SECONDS

6 = 40 SECONDS

E = 80 SECONDS

7 = 45 SECONDS

F = 85 SECONDS

Spin Down/Up Time

SCSI Interface Connector J2

The SCSI interface connector (J2) pin assignments are supplied for your convenience. All odd

numbered pins, except Pins 25 & 29 must be connected to ground. Pin 25 should be left open.

Pin 29 can be used for Synchronized Spindle operation. Pin 26 is reserved for terminator resistor

power source.

Pin

Signal

Pin

Signal

Pin

Signal

Pin

Signal

2

-Data Bit 0

16

-Data Bit 7

28

-Ground

40

-RST

4

-Data Bit 1

18

-Data Bit P

30

-Ground

42

-MSG

6

-Data Bit 2

20

Ground

32

-ATN

44

-SEL

8

-Data Bit 3

22

Ground

34

Ground

46

-C/D

10

-Data Bit 4

24

Ground

36

BSY

48

-REQ

12

-Data Bit 5

26

TRMPWR

38

ACK

50

-I/O

14

-Data Bit 6

Table 2: SCSI Interface Connector J2 Pin Assignments