Receiving frame front panel – StorCase Technology DE200i-S User Manual
Page 11

StorCase Technology, Inc.
DE200i-S User's Guide - Rev. D01
4
Introduction
Figure 3: Receiving Frame Front Panel
Receiving Frame Front Panel
(Figure 3)
Key Lock/Drive Power Switch: Performs three functions. The key lock assures
proper seating of the device carrier within the receiving frame, turns power to the
device carrier on and off, and prevents unauthorized removal or installation of the
carrier (when configured with a removable key). For the computer to access data
on the DE200i-S disk drive, the key must be turned counterclockwise to the locked
position.
The key lock/power switch can be configured with either a fixed (factory configu-
ration) or removable key as shown in Appendix C.
Unit ID Number Indicator (Figure 4): Displays the physical address of the
DE200i-S device carrier if the carrier is Installed and Locked in the receiving frame
or if the carrier is Removed from the receiving frame. If the carrier is Installed but
Not Locked in the receiving frame, a "u" will be displayed to indicate an unlocked
condition. The unit ID number is selected by means of the ID select switch inside
the receiving frame using a special alignment tool supplied with the DE200i-S.
Activity Indicator: A small dot next to the Unit ID Number which illuminates to show
when the host computer is accessing the data on the DE200i-S carrier. This dot will
flash during communication with the host computer.
Device Spin Down/Up Timer: May be disabled by removing Jumper J6 P1-P2
(Figure 5). The timer controls the length of time that the unit ID number display flashes
during device spin down/up, providing a visual indication of drive activity. Refer to
Figure 11 for switch settings.