Installing the receiving frame – StorCase Technology DE200i-S User Manual
Page 17
StorCase Technology, Inc.
DE200i-S User's Guide - Rev. D01
10
Installation
Figure 8: Receiving Frame Connector (J4) Pin Configuration
0427
Receiving Frame
Mother Board
Connector J4
Installed
at Factory
Reserved
19
20
1
13
2
14
From System ID0
From System ID1
From System ID2
Ground
Table 1: Receiving Frame Motherboard Connector J4 Pin Configuration
Pin 1
RESERVED
Pin 11
RESERVED
Pin 2
RESERVED
Pin 12
RESERVED
Pin 3
RESERVED
Pin 13
RESERVED
Pin 4
RESERVED
Pin 14
RESERVED
Pin 5
RESERVED
Pin 15
Ground
Pin 6
RESERVED
Pin 16
ID2
Pin 7
RESERVED
Pin 17
Ground
Pin 8
RESERVED
Pin 18
ID1
Pin 9
RESERVED
Pin 19
Ground
Pin 10
RESERVED
Pin 20
ID0
Installing the Receiving Frame
The drive should be installed into the carrier before installing the receiving frame into the
mounting bay of a computer or expansion chassis.
NOTE:
Use a #2 Phillips screwdriver during this procedure.
1.
Turn OFF power to the computer.
2.
Open the computer system according to the manufacturers instructions. If
necessary, temporarily remove any expansion boards that may make installation
difficult.
3.
To select the DE200i-S unit ID remotely through the computer system or external
expansion chassis, the appropriate cable from the system must be connected to
the ID select connector (J4) on the rear of the receiving frame as shown in Table
1 and Figure 8.