Installation
11
Mounting
Holes (Right)
Mounting
Holes (Bottom)
Front of Unit
Mounting
Holes (Left)
0364
IMPORTANT NOTE: In order to use remote ID selection from a computer or expansion
chassis, the Unit ID number on the DE200i-S receiving frame
must be set to "0" with the provided alignment tool. Refer to the
section "Selecting the Unit ID Number" later in this User's Guide
for the Unit ID selection procedure.
4.
With the drive carrier locked in place inside the receiving frame, install the
DE200i-S into the 5.25 drive opening in the computer or expansion chassis. Use
the appropriate guides to position the DE200i-S, and fasten it into place with the
four (4) #6-32 Phillips Pan Hd. screws provided. Figure 9 illustrates the location
of the mounting holes. Mounting holes are provided on each side and the bottom
of the receiving frame to accommodate a variety of mounting configurations. Use
the mounting holes which best suit the computer or expansion chassis
configuration.
Figure 9: Receiving Frame Mounting Holes
5.
Adjust the front of the receiving frame so the carrier slides freely in and out on
the receiving frame guides. The position of adjoining peripheral units may require
adjustment.
6.
To connect the drive to a Remote Activity LED in the computer system or
expansion chassis, connect the appropriate cable(s) to the receiving frame
motherboard as shown in Figure 5. Connect J6 Pins 4 & 6 to a remote activity
LED.
7.
Connect the I/O cable from the host adapter to the receiving frame. The Pin 1
indicator on the cable must be properly aligned. Refer to Figure 5 for the correct
Pin 1 location.
Make sure that only the last SCSI device is terminated. If the DE200i-S is at the
end of a daisy chain, the terminators on the receiving frame must be enabled.
If the DE200i-S is in the middle of a daisy chain, termination should be disabled
(factory default). Refer to jumper W2 in Figure 5.