28
© 2 0 0 3 d i r e c t e d e l e c t r o n i c s , i n c .
T
TW
WO
O--R
RE
ESSIISST
TO
OR
R T
TY
YP
PE
E:: If two resistors are used in the factory
door lock switch/key cylinder, the door lock switch/key cylinder
will read resistance to ground in both directions.
D
DE
ET
TE
ER
RM
MIIN
NIIN
NG
G T
TH
HE
E P
PR
RO
OP
PE
ER
R R
RE
ESSIISST
TO
OR
R V
VA
AL
LU
UE
ESS:: To
determine the resistor values, the door lock switch/key cylinder
must be isolated from the factory door lock system. For testing, use
a calibrated digital multimeter that is set to ohms.
IIM
MP
PO
OR
RT
TA
AN
NT
T::
To ensure an accurate resistance reading, do not touch
the resistor or leads during testing.
1.
Cut the output wire from the door lock switch/key cylinder in
half.
2.
Test with the meter from the switch side of the cut door lock
switch/key cylinder wire to a reliable ground source. Some good
ground references are the ground input source to the door lock
switch/key cylinder or the battery ground.
3.
Operate the door lock switch/key cylinder in both directions to
determine the resistor values. If the multimeter displays zero
resistance in one direction, no resistor is needed for that direc-
tion.
4.
Once the resistor value(s) is determined, refer to the wiring dia-
gram for proper wiring.