Troubleshooting guide maintenance, Audible feedback – Mighty Mule FM200 User Manual

Page 29

background image

13

rev 07.25.12

• On all gates weighing 250 lb. or more, routinely grease

the ball bearing hinges at least 4 times a year; more
frequently if the gates are near a coastal area.

• Apply silicone spray to a soft, dry cloth and clean the

push/pull tube at least once a month.

Audible Feedback

Symptom

Diagnosis

Check:

1 or more short beeps
upon power up

Circuit Board Powered
Up & Ready

• Normal Operation

Continuous beep after
power-up

Unit has learned new
transmitter code, releasing
the transmitter button will
shut off alarm.

Unit has entered “LEARN
LIMIT” mode. Releasing
the transmitter will turn off
alarm.

• Normal Operation

Rapid beeping

Circuit Board Senses an
Obstruction

• Path of Gate
• Gate for Level and Plumb
• Stall Force Adjustment
• Disconnect Safety Devices

1 beep with 20 seconds
off

Low Battery Condition

• Transformer or Solar Panel Voltage
• Battery Harness Connections
• Battery Under Load

2 beeps every 2 seconds

Position sensor is short
circuit.

• Arm Power Cable for Damage

1 beep with 2 seconds off

Arm Limit Switch Error

• Connections to Inputs
• Arm Power Cable for Damage

1 beep when attempting
to run the gate

Blown fuse
Battery is low or damaged
Loose Connection

• Check and replace fuse
• Test battery voltage
• Check all connections