LINK Systems Omni II Automatic Setups Module User Manual
Page 47
October 16, 2008
Manual Version 1.1
5-3
“CONFIGURE”
Allows
the
individual options such as counterbalance, cushion, and
slide adjust modules to be configured during initial installation of the
system and will not be used for production operation setup. Note that
this key is only available when the RUN/PROG keyed switch is in the
PROG position.
“JOG UP”
Press this softkey to move the slide up. A momentary push will
“pulse” the slide up once for fine control. If the key is held down for
more than about ½ a second, the slide will move up continuously until
the key is released.
“JOG DOWN”
Press this softkey to move the slide down. A momentary push will
“pulse” the slide down once for fine control. If the key is held down
for more than about ½ a second, the slide will move down
continuously until the key is released.
“AUTO ADJUST”
Press this softkey to automatically move the slide to the setpoint. An
auto adjust sequence always goes above the setpoint and then comes
down to it for consistency. Note that when an auto adjust sequence is
in progress, this key will change to CANCEL AUTO ADJUST. When
pressed under this circumstance, it will cancel the auto adjust sequence
and cause slide motion to stop.
“RESET”
Certain
errors
will
cause
the
auto setup module to generate a top stop
or cycle stop to the press. When this occurs, the RESET softkey will
appear. Before the press can be started again, the fault must be
corrected and this key must be pressed to clear the error condition.
Note that this is a restricted operation and an access code may be
required depending on system configuration as detailed in Section 2.
Section 5.1
Slide Adjust Operation
Each configured slide system has its own “box” on the screen (Figure 5.1 shows a setup with
only one slide adjust system). The title of the box has the shut height system name and the
mode the system is in (ON, OFF, or MANUAL). This box contains:
Setpoint
The desired position of the slide shut height adjustment. This number
may be changed by manual operator entry when the operator has access
via key or user code depending on the configuration of the system as
detailed in Section 2. The setpoint will also be changed to the required
slide setpoint for a previously stored job when that job setup is recalled
from memory and the system is ON. The units for this setpoint can be in
inches or millimeters depending on the configuration. See section 4.2.2
for details.
Actual Shutheight
The actual position of the slide shut height adjustment as indicated by a