LINK Systems Omni II Automatic Setups Module User Manual
Page 39
October 16, 2008
Manual Version 1.1
4-11
tolerance limits. To configure a particular air system, move the cursor to that system and press
the CONFIGURE SYSTEM softkey.
The slide adjust configuration screen is shown in Figure 4.6.
Stroke
Mode
Inch
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
PC STATUS
Counter OFF
EXIT
0
0
Program/Run Switch
TOP
Auto-Setup
Config
Slide 1 Configuration
Module:
Slide Slot:
Mode:
Shut Height Units
Upper Limit:
Lower Limit:
Tolerance:
Pulse Distance:
Pulse Time:
Resolver Turns:
Parameter Help
CHANGE
SETTING
1
1
ON
in
20.000 in
14.000 in
.004 in
.010 in
30 mses
100
System ignores setpoint but jog softkeys work.
System uses setpoint and job recalls will
change the setpoint.
System uses setpoint but job recalls will
NOT change the setpoint.
OFF
ON
MANUAL
-
-
-
CALIBRATE
Figure 4-6 Slide Configuration Screen
There are several parameters that must be configured in this screen. The editing cursor indicates
which parameter is currently selected. Softkey 1 (the uppermost vertical softkey) will change its
description based on the parameter and, when pressed, allows the currently selected parameter to
be changed. The up and down arrow keys move the editing cursor from one parameter to
another. See Appendix A for examples of setting up each kind of system. The features of this
screen are:
Help The
“Help”
box
at
the
bottom
of the screen changes depending on the
parameter that the editing cursor is currently on. It gives a short version of
how the parameter is used.
Module
Corresponds to the physical Automatic Slide Adjust module number to
which the slide adjust module is currently connected. This is a display
parameter only and cannot be changed.
Slide Slot
Corresponds to the physical slot number, SS1 or SS2, to which the slide
adjust module is currently plugged into. This is a display parameter only
and cannot be changed.