After installing the plug-on boards to the base card and selecting the correct Module Number,
slide the base card into the single slot card rack. The board slides into the two guides of the rack.
It is held in place with two knurled screws at the top and bottom of the board.
Section 3.1.3 Module Mounting
The OmniLink II Press Automation Control Automatic Setup module can be mounted in the
press control enclosure or it can be mounted in its own enclosure. If the unit is subject to shock
and vibration, shock mounts are required. Either the card rack assembly can be shock mounted
or the enclosure in which it is installed can be shock mounted.
In selecting the mounting location for the OmniLink II Press Automation Control Automatic
Setup module, the wiring connections for the unit should be considered. See Section 3.1.3 for
the necessary wiring connections. After the mounting location has been determined, the card
rack assembly can be secured with four screws. The mounting footprint is show in Figure 3.3.